Agency Listings & Certificates

您所在的位置:网站首页 lookup ul listing Agency Listings & Certificates

Agency Listings & Certificates

#Agency Listings & Certificates | 来源: 网络整理| 查看: 265

Agency Listing

Here you will find the Agency listing information relating to Resideo security products. This page is constructed around the following sections. Please select which section you require.

UL/CUL Listings How to acquire listing cards Definitions of Terms Definitions of Category Control Numbers ULC Listing Cards CSFM Certificates ETL Listings Government (NIST) ISO9001 UL 2075 UL/CUL Listings How to acquire listing cards

The following is a brief description of how to use UL’s website to acquire Listing cards.

1. Go to http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm

2. Type a model in the box next to Keyword

****You can also type a company name, part number, file number, etc.****

NOTE: Some problems you may encounter are:

a. Dashes and spaces may be an issue. [i.e. VISTA-128FB or VISTA 128FB]

b. Partial descriptions sometimes exist. [i.e. VISTA-128FB may not give you all Listed categories for that product. If you type 128FB also, you will get one additional that didn’t appear on the original search of the Vista-128FB - There are only a few of these that act in this manner].

3. The results of your search will bring you to another screen with selections in blue, such as UOJZ.S789 [which represent: Category Control Number. File Number].

4. Select one of these blue descriptors and you will go directly to the Listing cards for that category.

NOTE: This selected document will include every UL Listing in that product category for that corresponding company.

5. Now you may view/print these pages.

ADDITIONAL NOTES:

FOR US LISTINGS –

UOJZ – Control Units Systems which means that you will be viewing the COMMERCIAL FIRE Listings;

FOR CANADIAN LISTINGS

UOJZ7or 8 – Control Units Systems which means that you will be viewing the COMMERCIAL FIRE Listings.

Definitions of Terms Terms - Meaning The word "Burglar" Means "Commercial Burg" The word "Burglary" Means "Household Burg" The word "Accessory" Component suitable for use with control panels that support it The word "Sub-Assembly" Control Panel PCB suitable for use in one or more enclosures Samples of Basic Label Wordings - Meaning - Signal System Control Unit Commercial Fire Alarm Panel Signal System Control Unit Sub-Assembly Commercial Fire Alarm Panel pcb suitable for use in a specific enclosure Signaling Device Accessory for use with specific Commercial Fire Alarm Panels Household Fire Warning System Control Unit Household Fire Alarm Panel Household Fire Warning System Control Unit Accessory Accessory for use with specific Household Fire Alarm Panels Burglar Alarm System Control Unit Commercial Burg Alarm Panel Burglar Alarm System Control Unit Sub-Assembly Commercial Burg Alarm Panel pcb suitable for use in a specific enclosure Household Burglary Warning System Control Unit Household Burg Alarm Panel Household Burglary Warning System Control Unit Accessory Accessory for use with specific Household Burg Alarm Panels ACTUAL LABEL TEXT - Meaning Signal System Control Unit Commercial Fire Alarm Panel Also Suitable For Use As A Also Suitable For Use As A Burglar Alarm System Control Unit Commercial Burg Alarm Pane Signal System Control Unit Sub-Assembly Commercial Fire Alarm Panel pcb to be used in a specific enclosure Also Suitable For Use As A Also Suitable For Use As A Burglar Alarm System Control UnitSub-Assembly Commercial Burg Alarm Panel pcb to be used in a specific enclosure Signaling Device Accessory for use with specific Commercial Fire Alarm Panels Also Suitable For Use As A Also Suitable For Use As A Household Fire and Burglary WarningSystem Control Unit Accessory Accessory for use with specific Household Fire/Burg Alarm Panels And A Burglar Alarm System Accessory Accessory for use with specific Commercial Burg Alarm Panels Household Fire and Burglary WarningSystem Control Unit Household Fire/Burg Alarm Panel Household Fire and Burglary WarningSystem Control Unit Accessory Accessory for use with specific Household Fire/Burg Alarm Panels Household Fire and Burglary WarningSystem Control Unit Enclosure Household Fire/Burg Alarm Panel Enclosure **These are also suitable for use with pcb Sub-Assemblies** Household Fire and Burglary WarningSystem Control Unit Assembly Household Fire/Burg Alarm Panel pcb suitable for use in a specific enclosure Also Suitable For Use As A Also Suitable For Use As A Burglar Alarm Unit Sub-Assembly Commercial Burg Alarm Panel pcb suitable for use in a specific enclosure Household Fire and Burglary WarningSystem Control Unit Accessory Accessory for use with specific Household Fire/Burg Alarm Panels Also Suitable For Use As A Also Suitable For Use As A Burglar Alarm System Accessory Accessory for use with specific Commercial Burg Alarm Panels Definitions of Category Control Numbers

Definitions of Category Control Numbers which are found at the top of the UL Listing cards

Category Control Number (CCN)

ULcUL

Category Name Actual Meaning Applicable UL Standards Applicable ULC or CSA Standards Used For Canadian Certification ALVY ALVY7 Access Control System Units Access Control Unit UL294 Covered CSA 222 -205, M1983. AMCX AMCX7 Central Station Alarm Units Commercial Burg Alarm UL1610 ** CAN/ULC-S304-M88, "Central and Monitoring Station Burglar Alarm Units" and UL 1635, "Digital Alarm Communicator System Units." AMQV AMQV7 Connectors and Switches Contacts UL634 ULC C634 "Connectors and Switches for Use With Burglar alarm Systems". ANET ANET7 Holdup Alarm Units Commercial Burg Alarm UL636 ** CAN/ULC-S303-1991 (R1999), Local Burglar Alarm Systems and Units and CAN/ULC-S304-1988, Central and Monitoring Station Burglar Alarm Units. ANSR ANSR7 Intrusion Detection Unit Motion Detectors & Glass Breaks UL639 ** ULC-S306, "Intrusion Detection Units". AOTX AOTX7 Local Alarm Units Commercial Burg Alarm UL464 for Audibility requirements UL609 for constructional requirements ** CAN/ULC-S303, "Local Burglar Alarm Units and Systems" and CAN/ULC-S525, "Audible Signal Appliances. APAW APAW7 Police Station Alarm Unit Commercial Burg Alarm UL464 for Audibility requirements UL365 for constructional requirements ** CAN/ULC -S303-M91, "Local Burglar Alarm Units and Systems," CAN/ULC-S304-M88, "Central and Monitoring Burglar Alarm Units" and CAN/ULC-S525, "Audible Signal Appliances." APOU APOU7 Proprietary Alarm Units Commercial Burg Alarm UL1076 ** UL 1076, "Proprietary Burglar Alarm Units and Systems." DRQH DRQH7 Closed Circuit Television Equipment CCTV Equipment UL2044 CAN/CSA-C22.2 No. 1, "Audio, Video and Similar Electronic Equipment". MULQ MULQ7 Home Health Care Signaling Equipment Suitable for Home Health Care Use UL1637 No equivalent Canadian Standard. NBSX NBSX7 Household Burglar Alarm System Units Residential Burg Alarm UL1023 ** UL1023 "Household Burglar Alarm System Units". NWGQ NWGQ7 Information Technology Equipment Including Electrical Business Equipment IT Equipment and Telco-Connected Equipment UL1950 CAN/CSA-C22.2 No. 950 and CAN/CSA-C22.2 No. 60950, "Safety of Information Technology Equipment." UOJZ UOJZ7 Control Units, System Commercial Fire Alarm UL864 ** CAN/ULC-527, "Control Units for Fire Alarm Systems". UOXX UOXX7 Control Unit Accessories, System Commercial Fire Alarm UL864 ** CAN/ULC-S527-M87, "Control Units for Fire Alarm Systems". UROX UROX7 Smoke - Automatic Fire Detectors Residential & Commercial Smokes - No sounder required UL268 CAN/ULC 529 "Smoke Detectors for Fire Alarm Systems" UTGT UTGT7 Single and Multiple Station Smoke Detectors Residential Smokes - Sounder & Temporal Alarm required UL217 CAN/ULC-S531, "Smoke Alarms". UTOU UTOU7 Control Unit and Accessories - Household System Type Residential Fire Alarm UL985 ** CAN/ULC S545, "Residential Fire Warning System Control Units". ** Note: Any equipment with a digital communicator has been evaluated to UL1635. ULC Listing Cards

1. The following is a brief description of how to use UL’s website to acquire Listing cards.

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm

2. Type a model in the box next to Keyword

****You can also type a company name, part number, file number, etc.****

NOTE: Some problems you may encounter are:

a. Dashes and spaces may be an issue. [i.e. Vista-128FB or Vista 128FB]

b. Partial descriptions sometimes exist. [i.e. Vista-128FB may not give you all Listed categories for that product. If you type 128FB also, you will get one additional that didn’t appear on the original search of the Vista-128FB - There are only a few of these that act in this manner].

3. The results of your search will bring you to another screen with selections in blue, such as UOJZ.S789 [which represent: Category Control Number. File Number].

4. Select one of these blue descriptors and you will go directly to the Listing cards for that category.

NOTE: This selected document will include every UL Listing in that product category for that corresponding company.

5. Now you may view/print these pages.

ULC Website

CSFM Certificates

Step 1: Get the CSFM Certification number from the correlation sheet with corresponding Resideo part numbers.

 

How to find a CSFM Certification number:

GO TO CORRELATION SHEET and get CSFM Certification number

EXAMPLE: A VISTA-128FB Certification Number is 7165-1645:0123, where,

7165 is the Category Number 1645 is the Assigned Company Code 0123 is the Listing Index Number [sequential].

NOTE 1: The 1645 portion of the number is VERY Important.

Step 2: Once you’ve obtained the CSFM certificate number, go to Instructions on how to use CSFM’s search, below.

 

Instructions on how to use CSFM's search:

Step 1: Go to https://osfm.fire.ca.gov/divisions/fire-engineering-and-investigations/building-materials-listing/bml-search-building-materials-listing/

Step 2: Select “Resideo Security” for company name

Step 3: Click on SEARCH

Step 4: Select “desired certificate” for Listing

 

To Search for parts that are not found in the correlation sheet:

Step 1: Select the part’s category from the Sort by Categories option. (company and Listing options remain at “All Listings”)

Step 2: Click on SEARCH

Step 3: To find the desired part, click “Ctrl F” [FIND FEATURE] and enter the part number.

EXAMPLE: For 5193SD select 7272-Smoke Detector-Photoelectric from category and do search.

Enter 5193SD in the find feature window and click find. It will take you to certificate number 7272-1653:0210

ETL Listings

https://ramuk.intertekconnect.com/WebClients/ITS/DLP/products.nsf/$$Search?OpenForm

Government (NIST) Statement of Compliance UL 2050 AlarmNet network suitability for use in UL 2050 environments For Advanced Encryption - FIPS 197 approved.

Latest version - Cert # 979 for our Internet Devices is described on the NIST site as:

Alarmnet-i communications uses AES in CBC mode with 256-bit key. The module is embedded in the entire family of Alarmnet-i communicators including (but not limited to) 7845i-GSM, 7845i-GSMCN, 7845i-GSMG, iGSMCF, and 7847i. Alarmnet-i's AES software module is written in C and encapsulates encryption/decryption services for Alarmnet-i

Previous version - Cert # 127 for our Internet Devices is described on the NIST site as:

The AlarmNet-i is used in our 7810ir, 7810ir-ent, 7845i, 7845i-ent and 8132 devices. The software module handles the encryption function for each product and is an encapsulated C++ module. 

For Triple DES Encryption - FIPS 46-3 approved.

Cert. # 195 for the AC Communicator model is described on the NIST site as:

The AC Communicator Module (P/N 472491D3) is used to encrypt and transmit security system data over public telephone line, RS232 and DVAC to proprietary central station automation equipment.

Get information about the GOVHS-KT1 product kit for UL 2050 applications. If you have questions concerning UL 2050,please contact our support.

ISO9001

Download ISO certificate

UL 2075 5800CO UL 2075 Compatibility

Below is a list of Resideo products that meet the UL 2075 System Listing when used with the 5800CO. Please be sure to check this site frequently as we continue to add products.

Product  Revision Controls LYNXR-I Series 17 or higher VISTA-21iP 1.0 or higher VISTA-21iPSIA 1.0 or higher VISTA-20P 7.0 or higher VISTA-15P 6.1 or higher VISTA-10P 4.0 or higher VISTA-20PSIA 7.0 or higher VISTA-15PSIA 6.1 or higher VISTA-10PSIA 4.0 or higher FA168CPS 7.0 or higher FA148CP 6.1 or higher FA130CP 4.0 or higher FA168CPSSIA 7.0 or higher FA148CPSSIA 6.1 or higher FA130CPSSIA 4.0 or higher Keypads 6160 V101 or higher 6160CR V101 or higher 6150 V102 or higher  6148 V102 or higher FA570KP V101 or higher FA220KP V102 or higher